< img height="1" width="1" style="display:none" src="https://www.facebook.com/tr?id=693716185752290&ev=PageView&noscript=1" />
News
News
All News

SolArk-5K-2P-N-Residential Hybrid Inverter

17
Apr. 2024

Input Data (PV)

Max.   Allowed PV Power (STC)

6,500W

Rated   MPPT Operating Voltage Range

175   - 425V

MPPT   Voltage Range

150   - 500V

Startup   Voltage

125V

Max.   Input Voltage 1

500V

Max.   Operating Input Current per MPPT

10A   (self-limiting)

No.   of MPP Trackers

2

No.   of PV Strings per MPPT

2

Max.   AC Coupled Input

9,600W

Output Data (AC)

Nominal   AC Voltage

120/240V,   120/208V, 220V

Grid   Frequency

50   / 60Hz

Real   Power, max continuous

5,000W

Max.   Output Current

20.8A

Peak   Apparent Power (10s, off-grid) 16,000VA @ 240V P

16,000VA   @ 240V

Peak   Apparent Power (100ms, off-grid)

25,000VA   @ 240V

Max   Output Fault Current (100ms)

104A

Max.   Grid Passthrough Current

63A

Power   Factor Output Range

+/-   0.9 adjustable

Backup   Transfer Time

4ms

CEC   Efficiency

96.5%

Max   Efficiency

97.5%

Design   (DC to AC)

Transformerless   DC

Stackable

No

Battery Input Data (DC)

Battery   Technologies

Lithium   / Lead Acid

Nominal   DC Voltage

48V

Operating   Voltage Range

43   - 63V

Capacity

50   — 9900Ah

Max.   Battery Charge / Discharge Current

185A

Charging   Controller

3-Stage   with Equalization

Grid   to Battery Charging Efficiency

96.0%

External   Battery Temperature Sensor (BTS)

Included

Automatic   Generator Start (AGS)

2   Wire Start - Integrated

BMS   Communication

CANBus   & RS485 MODBUS

General   Data


Dimensions   (H x W x D)

750   x 450 x 254 mm (29.5 x 17.7 x 10 in)

Weight

35.4   kg / 78 lb.

Enclosure

IP65   / NEMA 3R

Ambient   Temperature

-25~55°C,   > 45°C Derating

Noise

<   30 dB @ 25°C (77°F)

Idle   consumption - No Load

60W

Communication   and Monitoring

Wi-Fi   & LAN Hardware Included

Standard   Warranty

10   Years

Protection and Certifications

Certifications   and Listings

UL1741-2010/2018,   IEEE1547a 2003/2014, FCC 15 Class B, UL1741SB, CA Rule 21, HECO Rule 14H

PV   DC Disconnect Switch — NEC 240.15

Integrated

Ground   Fault Detection — NEC 690.5

Integrated

PV   Rapid Shutdown Control — NEC 690.12

Integrated

PV   Arc Fault Detection — NEC 690.11

Integrated

PV   Input Lightning Protection

Integrated

PV   String Input Reverse Polarity Protection

Integrated

AC   Output Breaker - 63A

Integrated

250A   Battery Breaker / Disconnect

Integrated

Surge   Protection

DC   Type II / AC Type II


隐藏文字