Minimum SOC need to be set up in the VRM system or Cerbo GX. The setup steps are as follows.

1. Click enter ,into menu page.

Click enter ,into menu

2. Click Setting.

Click Setting

3. Click ESS.

Click ESS

4. Click Minimum SOC, set it to 10%,and save.

Click Minimum SOC, set it to 10%,and save



Sol-Ark

Sol-Ark

1. Click the settings icon.

Click the settings icon

2. Click the Battery Setup icon.

Click the Battery Setup icon

3. Click the Discharge. And set the value at the position as shown below.

Click the Discharge

Discharge setting

A.   Shutdown: 10%

B.   Low Batt: 20%

C.   Restart: 25%

D.   Batt Resistance: 10mOhms

E.   Batt Charge Efficiancy: 98.0%


4. After completing the settings, click "OK" to save.

Click the Discharge


Solis

There are two ways to set Minimum SOC, one is set on inverter screen, the other is set on phone. For models like S5, RHI, etc., which have an operation panel, you can set it directly on the inverter screen. For the new S6 models with Wifi module, you can set it by the mobile app.

Set on the inverter screen.

图片11.webp

1. After Battery Select, there are two parameters need to be defined in next page.

图片12.webp

OverDischg SOC (10%~40%, default 20%

--Inverter will not discharge the battery when the OverDischg SOC is reached.

Battery self-discharge is unavoidable,SOC may go lower than the limit if the battery can't get charged for a long period of time. 

ForceCharge SOC (5%~OverDischg SOC, default 10%

--To prevent the battery going into sleep mode, when the ForceCharge SOC is reached, inverter will charge the battery using the power from either PV or Grid.


2. Set OverDischg SOC to 20%.

图片13.webp

3. Set ForceCharge SOC to 10%, and saved.

图片14.webp

Set on the SolisCloud APP.

图片15.webp

1.After Battery type Select to Pytes , ForceCharge SOC and OverDischg SOC can be defined in battery setting.

微信截图_20240626163734.webp

2. In battery setting interface ,set OverDischg SOC to 20% ,set ForceCharge SOC to 10%,and save.

图片16.webp


Luxpower

图片22.webp

1. Click the setting icon.

图片23.webp


2. Click the discharge,and set Stop discharge SOC to 10%, save.

图片24.webp

Settings for battery force discharge within certain time period. In the preset time period, the inverter will discharge battery at the power set by “discharge power”, until battery SOC or voltage reaches “Stop discharge ”value.



Growatt

图片25.webp

1. After program 05 select Li,and protocol select to L51, there is SOC can be set in program 21.

图片26.webp图片27.webp

2. Turn to program 21,set Min soc to 10%, and save.

图片28.webp

图片29.webp




Megarevo

图片30.webp

After BAT TYPE set to Lithium, DISC-DEPTH can be set to 90%.

图片31.webp


1. Enter password 00000,select BAT TYPE to Lithium.

图片32.webp

2. Enter to DISC-DEPTH interface,set Grid DOD to 90%,set OFF Grid DOD to 90%.

微信截图_20240626164200.webp


Grid DOD/ OFF Grid DOD: When the battery discharge is higher than the set parameter, the inverter generates a battery low voltage alarm.

Return: When a low-voltage alarm is generated, the alarm is cleared if the battery charge is higher than the specified amount. 



Must

图片33.webp

1. After the inverter and battery communicated successfully, turn to program 38 ,set stop discharge SOC to 10%


图片34.webp


SMA

1. After the inverter and battery communicated successfully,connect to SMA WiFi. Turn on your computer and Open your browser, type in the web bar the URL: 192.168.12.3 .Then login.

图片35.webp



2. Click the Device parameters and click Edit parameters.

图片36.webp


3. Click the battery,then click Areas of application.

图片37.webp


4. Set Minimum SOC to 10%.

图片38.webp

5. Save.

图片39.webp